DÜNA Plate Anchor Metal
Scope of Application/strong>
- Ventilated curtain facades
- Concrete ceilings/walls
(e.g. underground car park, basement ceiling) - Fixing element for insulation boards
and especially hard insulation materials - Mounting substrates: concrete, solid bricks
Technical Data
Plate: Ø 76 mm
Material plate and nail: Galvanised or stainless steel
Material shaft: Aluminium
Bore hole: Ø 6.5 mm
Bore hole depth: 40 mm min
Installation depth: 30 mm min
4–5 pieces per m2 recommended
Installation
- Mounting of the insulation
- Drill a bore hole Ø 6.5 mm
- Insert the plate anchor, the plate sits flush on the insulation
- Drive in the pre-mounted expansion nail